Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
J Dent ; 135: 104563, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37270024

RESUMO

OBJECTIVES: To investigate the impact of the COVID-19 pandemic in the teaching of prosthodontics, on the 5th course of the Bachelor's degree in Dentistry in Spain. METHODS: In June 2021, a two-section survey was submitted to the coordinators of prosthodontics of the 23 Spanish faculties of Dentistry. The first section was focused on the theoretical lessons, seminars, and clinical discussion sessions. The second part relied on the clinical teaching and the implemented preventive measures. RESULTS: The response rate was 100%. By the end of the 2020-21 course, both the theoretical and practical teaching were replaced by online activities, returning to face-to face in 2021-22. While most participants preferred in-person seminars and clinical discussion sessions, concerning the theory, comparable percentages of professors chose either face-to-face or blended learning (BL). The students' satisfaction with BL is high, but they seem more attentive in-person. At the beginning of the pandemic, the most common emergency in prosthodontics was debonding. Overall, a low concern about cross-infection was noticed. The barrier measures were the mainly adopted for prevention. CONCLUSIONS: Although the BL is appreciated in prosthodontics for theoretical lessons, face-to-face teaching appears to be the best option for seminars and clinical case discussions. The students are satisfied with BL. CLINICAL SIGNIFICANCE: In the face of the COVID-19 pandemic, the Spanish faculties of Dentistry responded quickly to continuing offering quality education through an accelerated digitization process that has created a new paradigm. Detailed analyses of these changes may help establish plans to respond systematically to unforeseen emergencies.


Assuntos
COVID-19 , Pandemias , Humanos , Espanha/epidemiologia , Prostodontia , COVID-19/prevenção & controle , Aprendizagem , Ensino
2.
J Dent ; 132: 104470, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36842624

RESUMO

OBJECTIVES: To compare the fracture resistance (FR) of three combinations of materials for full-arch maxillary implant-supported hybrid prostheses (HPs) with short cantilevers (≤ 10 mm). METHODS: Maxillary HPs were fabricated and classified as follows (n = 5 each): Group-1 (CC-A, control): acrylic-resin-veneered Co-Cr frameworks; Group-2 (CF-A): acrylic-resin-veneered carbon-fiber mesostructures; and Group-3 (CF-R): composite-resin-veneered carbon-fiber frames. Specimens were thermal-cycled (5,000 cycles; 5 °C-55 °C; dwell time: 30 s). Vertical loads were applied until failure, first at the 10-mm-long cantilever (LC), and, afterwards, at the anterior region (AR), using a universal testing machine (crosshead speed: 0.05 mm/s). The fracture pattern was assessed by stereomicroscope and SEM. The one-way ANOVA, the Bonferroni, and the independent samples t tests, were run (α= 0.05). RESULTS: At LC, CF-A, and CC-A samples exhibited the highest FR values (p< 0.001), showing no differences to each other. At AR, CC-A specimens recorded the highest FR, followed by CF-A samples (p< 0.001). CF-R HPs displayed the lowest FR at both locations (p< 0.001). The only group with differences between the tested sites was the CC-A, the AR being more resistant (p< 0.001). Most CC-A and CF-A HPs failed cohesively. CF-R prostheses mainly failed adhesively. CONCLUSIONS: Maxillary HPs with short cantilevers (≤ 10 mm) made of Co-Cr or carbon-fiber veneered with acrylic resin demonstrated an adequate mechanical resistance (> 900 N). CLINICAL SIGNIFICANCE: For maxillary HPs with cantilevers up to 10 mm, acrylic-veneered carbon- fiber mesostructures may be recommended, whereas coating carbon-fiber frames with composite resin seems not suitable.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Resinas Acrílicas/química , Resinas Compostas/química , Teste de Materiais
3.
J Prosthet Dent ; 2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36109260

RESUMO

STATEMENT OF PROBLEM: The lack of consensus regarding a standardized set of outcome measurements and noncompliance with current reporting guidelines in clinical trials of tooth-supported fixed dental prostheses (FDPs) hamper interstudy comparability, compromise scientific evidence, and waste research effort and resources in prosthetic dentistry. PURPOSE: The primary objective of this systematic review was to identify all primary and secondary outcome measurements assessed in randomized controlled trials (RCTs) of tooth-supported FDPs. Secondary objectives were to assess their methodological quality by using the Cochrane Collaboration's risk of bias tool (RoB, v2.0) and their reporting quality by means of a standardized 16-item CONSORT assessment tool through published reports. MATERIAL AND METHODS: An electronic search was conducted in MEDLINE, EMBASE, and Cochrane library to identify all RCT-related articles published in the past 10 years. Differences in RoB were tested with the Pearson chi-square test, and those in CONSORT score with the Student t test. RESULTS: A total of 64 RCTs from 79 publications were deemed eligible. The diversity of outcome measures used in the field is apparent. Twenty percent of the included studies had a low RoB, 79% showed some concerns, and 1% had a high RoB. The mean ±standard deviation CONSORT compliance score was 22.56 ±3.17. Trials adhered to the CONSORT statement reported lower RoB than those that did not adhere (P<.001). RCTs with a low RoB reported more comprehensive adherence to CONSORT guidelines than those with some concerns (MD 4 [95% CI 1.52-6.48]; P=.004). CONCLUSIONS: A standardized core outcome reporting set in clinical research on tooth-supported FDPs remains evident. Adherence to the CONSORT statement continues to be low, with some RoB concerns that can be improved.

4.
J Dent ; 117: 103887, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34762987

RESUMO

OBJECTIVES: This research aimed to compare the oral health-related quality of life (OHRQoL) between fully dentate subjects and edentulous patients wearing implant-supported fixed partial dentures (i-FPDs). The clinical conditions of both types of restorations were evaluated. METHODS: Participants were assigned to: Group-1 (SR, n = 50): screw-retained i-FPD wearers; Group-2 (CR, n = 50): cement-retained i-FPD wearers; and Group-3 (ND, n = 50): dentate subjects with a healthy natural dentition (controls). Patients answered the OHIP-14sp and QoLIP-10 questionnaires. Data related to sociodemographics, prosthesis features, peri­implant status, complications, and subjective evaluations, were compiled. Potential modulators of the OHRQoL and the i-FPDs' clinical conditions were assessed using non-parametric tests (α= 0.05). RESULTS: ND individuals were the least satisfied (OHIP-14sp; p< 0.001). Both prosthodontic groups reported similar levels of wellbeing, excluding the speaking difficulties, which were lower for SR wearers as shown by both scales (p = 0.001). The most discontented patients (OHIP-14sp) were: women (p = 0.022), under 65 years (p = 0.03), without partner (p< 0.001) and having a crown (p = 0.033). The level of education/schooling also affected the OHIP-14sp scores (p< 0.001). Implant mobility and peri­implantitis were more frequent among CR wearers (p-values= 0.008 and 0.05, respectively). CONCLUSIONS: The OHRQoL of both prosthodontic groups was comparably higher than that of the dentate subjects, who were the most nonconformist. The self-perceived satisfaction was mainly modulated by sociodemographic factors. CLINICAL SIGNIFICANCE: Overall, the retention system did not impact the OHRQoL, prosthetic problems, and subjective evaluations of i-FPD wearers. However, the cementation may increase the risk of peri­implant diseases.


Assuntos
Revestimento de Dentadura , Qualidade de Vida , Parafusos Ósseos , Estudos Transversais , Prótese Dentária Fixada por Implante , Feminino , Humanos , Saúde Bucal , Satisfação do Paciente
5.
J Dent ; 116: 103902, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34822914

RESUMO

OBJECTIVES: This in vitro study aimed to find the best combination of mesostructure and veneering materials for full-arch implant-supported hybrid prostheses (HPs) in terms of the fracture resistance (FR) of their cantilevers. METHODS: Three groups (n = 5 each) of maxillary HPs were fabricated: Group-1 (CC-A, control): Co-Cr frameworks coated with acrylic resin; Group-2 (CF-A): carbon fiber veneered with acrylic resin; and Group-3 (CF-R): carbon fiber coated with composite resin. All specimens were submitted to 5,000 thermal cycles (5 °C - 55 °C, dwell time: 30 s), and subjected to a single cantilever bending test in a universal testing machine (crosshead speed: 0.5 mm/min) until failure. The fracture pattern was assessed using stereo microscope and SEM. The one-way ANOVA and Bonferroni tests were run (α= 0.05). RESULTS: The FR yielded significant differences among the three groups (p< 0.001). CC-A samples reached the highest FR values (p ≤ 0.001), whereas both CF-A and CF-R HPs exhibited the comparably (p = 0.107) lowest FR. CC-A specimens failed cohesively (100%): mostly without chipping (80%). CF-A mesostructures were always broken at the connections of the distal implants. CF-R prostheses often failed adhesively (80%). CONCLUSIONS: The HPs made of Co-Cr veneered with acrylic demonstrated the best mechanical behavior, being the only group whose 13-mm long cantilevers exceeded the clinically acceptable FR of 900 N. The HPs constructed with carbon fiber frameworks showed, additionally, more unfavorable fracture patterns. CLINICAL SIGNIFICANCE: For HPs with cantilevers up to 13 mm, Co-Cr mesostructures coated with acrylic may represent the optimum combination of materials.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Resinas Acrílicas , Fibra de Carbono , Facetas Dentárias , Teste de Materiais
6.
J Dent ; 114: 103756, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34333055

RESUMO

OBJECTIVES: This observational cross-sectional study aimed to evaluate and compare the oral health-related quality of life (OHRQoL) and clinical performance between dentate subjects and edentulous patients restored with conventional dentures or implant overdentures. METHODS: 85 edentulous patients were grouped as follows: Group-1 (CD): conventional denture wearers (n = 42), and Group-2 (IO): implant-retained overdenture wearers (n = 43). For the OHRQoL comparisons, a control group of subjects with a healthy natural dentition (Group-3, ND; n = 50) was included. Participants completed three validated questionnaires (OHIP-14sp, OHIP-20sp, and QoLIP-10). Socio-demographic data, prosthesis-related factors, clinical condition of the mouth, and patient subjective evaluations, were gathered. Descriptive and non-parametric probes were run (α = 0.05). RESULTS: The ND group was the most unsatisfied (OHIP-14sp; p ≤ 0.001). The OHIP-20sp attributed significantly worse Psychological disability (p = 0.029) and Handicap (p = 0.027) to CD wearers when compared to IO wearers. The CD group showed the significantly highest need for relining (p = 0.041), and the lowest retention (p = 0.011). The OHIP-14sp disclosed a significantly worse OHRQoL for those volunteers who had a job (p = 0.003), a basic education instead of a secondary one (p = 0.022), and no partner (p = 0.006). CONCLUSIONS: The overall OHRQoL was comparable for both prosthodontic groups, being modulated by socio-demographic and prosthesis-related features. Nonetheless, CD wearers presented prosthetic complications more frequently. CLINICAL SIGNIFICANCE: While dentate subjects were the most critical about their oral condition and its repercussion in their life, implant overdenture wearers tended to observe a better OHRQoL and clinical performance compared to conventional denture wearers.


Assuntos
Implantes Dentários , Qualidade de Vida , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Humanos , Saúde Bucal , Satisfação do Paciente
7.
J Dent ; 94: 103298, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32067997

RESUMO

OBJECTIVES: To investigate the impact of the retention system (screwed or cemented) of implant fixed dental prostheses (i-FDPs) on the peri-implant health, prosthesis' state, patient self-evaluation of functionality and aesthetics, and oral health-related quality of life (OHRQoL). METHODS: 35 participants were classified into two groups according to the retention system of their metal-ceramic i-FDPs. For the analysis of peri-implant health and prosthetic complications, the implant units were individually assessed. Group 1 (SPD; n = 22): implant units for screwed i-FDPs; and Group 2 (CPD; n = 36): implant units for cemented i-FDPs. Data related to socio-demographics, design and installation of the superstructures, peri-implant condition, prosthetic complications, functionality, and aesthetics, were gathered. Patients answered the Oral Health Impact Profile (OHIP-14sp) questionnaire. Descriptive and parametric probes were run to evaluate the impact scores considering the study variables (α = 0.05). RESULTS: The plaque index, gingival index, functionality, aesthetics, and global evaluation made by the patient recorded significantly better results for the SPD group. The most affected OHIP-14sp domain was 'Physical pain', followed by 'Psychological discomfort', and 'Functional limitation'. The subscales: 'Functional limitation', 'Physical disability', and 'Social disability', attributed significantly worst OHRQoL to CPD users. CONCLUSION: A major presence of peri-implant disease, together with a worse functionality, aesthetics, and patient satisfaction were recorded in cemented i-FDPs with respect to the screwed ones. CLINICAL SIGNIFICANCE: The retention system of i-FDPs can impact the peri-implant health, the subjective functional and aesthetic evaluation of the restoration, and the patients' OHRQoL; the screw retention providing superior results than the cementation.


Assuntos
Implantes Dentários , Qualidade de Vida , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Revestimento de Dentadura , Prótese Parcial Fixa , Humanos , Saúde Bucal
8.
J Dent ; 88: 103161, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31255639

RESUMO

OBJECTIVES: To evaluate the influence of bone type in terms of bone density and cortical bone thickness, on the stresses induced by two implants under compressive and oblique loads. METHODS: A numerical simulation technique based on the finite element method was applied. Two implant types (M-12 and Astra Tech) were introduced in a model matrix whose geometry was extracted from a real CBCT radiograph of the posterior mandibular region. The Young's module and Poisson's coefficient of the bone qualities described by Misch were calculated. Loads with amplitude of 400 N were exerted in two directions: compressive and 15° oblique to 5 mm above the uppermost part of the implant. RESULTS: The von Misses variant was analysed. Both implant types presented greater tension in the ​​cortical bone area than in the ​​trabecular bone region under compressive loading. For the oblique load condition, the stresses obtained in the cortical zone were significantly higher than those registered as a consequence of compressive loads in both implant types. CONCLUSIONS: Regardless of bone type, the M-12 implants presented lower tensions in the cortical bone than did the Astra implants. The tensions recorded for D3 and D4 bone types in the trabecular zone surrounding the M-12 implants were greater than those recorded for the Astra implants. CLINICAL SIGNIFICANCE: For both compressive and oblique loads, good mechanical behaviour was observed. The decrease in bone quality determines a worse stress distribution, and the cortical bone is overloaded. An efficient distribution of the forces may increase the implants' longevity.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/métodos , Mandíbula/diagnóstico por imagem , Simulação por Computador , Planejamento de Prótese Dentária , Módulo de Elasticidade , Análise de Elementos Finitos , Humanos , Estresse Mecânico
9.
Polymers (Basel) ; 11(4)2019 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-31027245

RESUMO

Polymethyl methacrylate (PMMA) and lithium disilicate are widely used materials in the dental field. PMMA is mainly used for the manufacture of removable prostheses; however, with the incorporation of CAD-CAM technology, new applications have been introduced for this material, including as a provisional implant attachment. Lithium disilicate is considered the gold standard for definitive attachment material. On the other hand, PMMA has begun to be used in clinics as a provisional attachment until the placement of a definitive one occurs. Although there are clinical studies regarding its use, there are few studies on cell reorganization around this type of material. This is why we carried out an in vitro comparative study using discs of both materials in which human gingival fibroblasts (HGFs) were cultured. After processing them, we analyzed various cellular parameters (cell count, cytoskeleton length, core size and coverage area). We analyzed the surface of the discs together with their composition. The results obtained were mostly not statistically significant, which shows that the qualities of PMMA make it a suitable material as an implant attachment.

10.
Med. oral patol. oral cir. bucal (Internet) ; 23(6): e733-3741, nov. 2018. tab
Artigo em Inglês | IBECS | ID: ibc-176396

RESUMO

BACKGROUND: To evaluate, over a 2-year period, the treatment outcomes for maxillary full-arch fixed dental prostheses (FDPs) supported by a combination of both tilted and axially-placed implants and to compare the marginal bone loss (MBL) and implant survival rates (SR) between tilted and axial implants. MATERIAL AND METHODS: A retrospective study has been carried out. Thirty-two patients (16 males and 16 females) treated with maxillary full-arch FDPs were included in this retrospective study. A total of 187 implants were inserted to rehabilitate the fully edentulous maxillary arches: 36% of them were tilted (T group, n = 68) and the remaining 64% were axially placed (A group, n = 119). From the total, 28% of the implants (n=53) were immediately loaded with screw-retained provisional acrylic restorations, whereas 72% underwent conventional delayed prosthetic loading 6 months post-operatively. Definitive restorations were hybrid implant prostheses (metal framework covered with high-density acrylic resin) and metal-ceramic screw-retained implant prostheses, and were placed 6 months after surgery. Such definitive restorations were checked for proper function and aesthetics every three months for two years. Peri-implant marginal bone levels were assessed by digital radiographs immediately after surgery and MBL was assessed at definitive implant loading (baseline) and 2 years afterwards. RESULTS: The 2-year implant SR were 100% for axially placed implants and 98.5% for tilted implants. No significant differences were found amongst the A and T implant groups. Marginal bone loss measured at 2 years after definitive prosthetic loading was of -0.73 ± 0.72 mm (maximum MBL of 1.43 mm) for axially positioned implants vs. -0.51 ± 0.92 mm for tilted implants (maximum bone 1.45 mm). Differences in MBL were statistically significant when comparing immediately and delayed loaded implants. CONCLUSIONS: Based on the results of this retrospective clinical study, full-arch fixed prostheses supported by a combination of both tilted and axially placed implants may be considered a predictable and viable treatment modality for the prosthetic rehabilitation of the completely edentulous maxilla


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Implantação Dentária Endóssea/métodos , Maxila/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
11.
J Dent ; 73: 97-104, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29678585

RESUMO

OBJECTIVES: This study aims to evaluate the fracture load of differently fabricated 3-unit posterior fixed dental prostheses (FDPs) with an intermediate pontic. METHODS: Fifty sets of two stainless-steel abutments were randomly assigned to five groups (n = 10 each) depending on the material and technique used for manufacturing the FDPs: (1) Metal-ceramic (MC, control); (2) Lava Zirconia (LZ, bi-layered); (3) Lava Plus (LM, monolithic); (4) VITA In-Ceram YZ (YZ, bi-layered); and (5) IPS e-max ZirCAD (ZZ, bi-layered). After being luted to the dies, all FDPs were submitted to thermo-mechanical cycling (120,000 masticatory cycles, 50 N; plus 774 thermal cycles of 5 °C/55 °C, dwell time: 30 s). Samples were then subjected to a three-point bending test until fracture in a universal testing machine (cross-head speed: 1 mm/min). Fracture load of the veneering ceramic (VF) and total fracture load (TF) were recorded. Microstructure and failure patterns were assessed. Data was analysed using one-way ANOVA and Tukey HSD post-hoc tests (α = 0.05). RESULTS: MC restorations recorded higher VF and TF values than did zirconia FDPs (p = 0.0001), which showed no between-group differences. Within the bi-layered groups, TF was significantly higher than VF. LM pieces registered lower average grain size than did LZ specimens (p = 0.001). Overall, the connector was the weakest part. CONCLUSIONS: All of the groups tested could withstand clinical chewing forces in terms of average fracture load. Zirconia-based samples performed similarly to each other, but showed lower mean fracture load values than did metal-ceramic ones. CLINICAL SIGNIFICANCE: Monolithic zirconia may be recommendable for solving the chipping problem.


Assuntos
Cerâmica/química , Materiais Dentários/química , Prótese Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Ligas Metalo-Cerâmicas/química , Zircônio/química , Análise de Variância , Desenho Assistido por Computador , Dente Suporte , Colagem Dentária , Porcelana Dentária/química , Facetas Dentárias , Planejamento de Dentadura , Prótese Parcial Fixa , Cimentos de Ionômeros de Vidro , Humanos , Teste de Materiais , Distribuição Aleatória , Aço Inoxidável/química , Estresse Mecânico
12.
Med. oral patol. oral cir. bucal (Internet) ; 23(1): e86-e91, ene. 2018. tab
Artigo em Inglês | IBECS | ID: ibc-170309

RESUMO

Background: Head and neck cancer are one of the most common neoplasm pathologies in humans. The aim of this study was to analyze the type, characteristics, treatment and evolution of oral neoplasm or precancerous lesion in a sample of Andalusian population (Spain) derived from the Oncology Rehabilitation Hospital Unit during a period of 20 years. Material and Methods: A retrospective descriptive study was carried out during the years 1991 and 2011 analyzing the type, characteristics, treatment and follow-up of oral neoplasm in the Oral and Maxillofacial Surgery Unit of the Universitary Hospital "Virgen del Rocío". The inclusion criteria were patients whose underlying pathology was any type of benign or malignant neoplasm or presence of precancerous lesion that, after treatment, had been referred to the Prosthetic Rehabilitation Unit. Results: Of the initial analyzed sample of 60 patients, only 45 patients met the inclusion criteria. Of the final sample analyzed, 31 subjects were men (68.9%) and 14 women (31.1%) (p = 0.0169). The mean age of the sample was 57 years ± 13.83, been more frequently in older people with more than 50 years (73.3%) (p = 0.0169). The most common type of neoplasm was epidermoid carcinoma (64.4%). The site most frequently found in squamous cell carcinoma was the floor of the mouth (31%). The most frequent treatment modality was surgery with postoperative radiotherapy (42.2%). All patients had a minimum follow-up of 5 years, and a recurrence in this period was identified in 11.1% of the sample. Multivariate logistic regression showed a statistically significant association for the variables age (p = 0.0063) and smoking (p = 0.0434). Conclusions: Epidermoid carcinoma is the most frequent tumor in the oral cavity, where increase age and smoking are confirmed as associated risk factors (AU)


No disponible


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Neoplasias de Cabeça e Pescoço/epidemiologia , Carcinoma de Células Escamosas/epidemiologia , Fatores de Risco , Alcoolismo/epidemiologia , Tabagismo/epidemiologia , Boca/patologia , Espanha/epidemiologia , Estudos Retrospectivos , Carcinoma de Células Escamosas/radioterapia , Carcinoma de Células Escamosas/cirurgia , Modelos Logísticos , Análise Multivariada , Hábitos
13.
J Prosthodont Res ; 62(1): 10-23, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28735678

RESUMO

PURPOSE: To evaluate the current status of all-ceramic inlay-retained fixed dental prostheses (CIR-FDPs) for the replacement of posterior teeth. STUDY SELECTION: Screening of titles and abstracts, full-text analysis for inclusion eligibility, quality assessment, data extraction and evaluation of the scientific evidence were performed independently by two reviewers. The electronic databases MEDLINE/PubMed, EMBASE, Cochrane Central Register of Controlled Trials, and Compludoc were searched with no restriction to publication date or language. The quality of the studies was evaluated through: the original 'QDP' ('Questionnaire for selecting articles on Dental Prostheses') (for research papers); the 'Guidelines for managing overviews' of the Evidence-Based Medicine Working Group (for reviews); the Cochrane risk of bias tool; and the GRADE scale for grading scientific evidence. RESULTS: This review started with 4942 articles, which were narrowed down to 23 according to the selection criteria. The data was not statistically treated because of the heterogeneity of the studies. Zirconia-based CIR-FDPs may be recommended for restoring posterior single missing teeth, although the prosthesis/tooth bonded interface has yet to be improved. The addition of lateral wings to the classical inlay preparation seems promising. The weakest parts of CIR-FDPs are the connectors and retainers, while caries and endodontic problems are the most common biological complications. The fabrication of CIR-FDPs with monolithic zirconia may eliminate chipping problems. CONCLUSIONS: A three-unit CIR-FDP is a viable treatment option for replacing a posterior missing tooth. Appropriate case selection, abutment preparation and luting procedures may be decisive for clinical success.


Assuntos
Cerâmica , Materiais Dentários , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Prótese Parcial Fixa , Restaurações Intracoronárias , Perda de Dente/reabilitação , Bases de Dados Bibliográficas , Humanos , Zircônio
14.
Med. oral patol. oral cir. bucal (Internet) ; 22(5): e643-e650, sept. 2017. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-166661

RESUMO

Background: Odontogenic cysts are defined as those cysts that arise from odontogenic epithelium and occur in the tooth-bearing regions of the jaws. Cystectomy, marsupialization or decompression of odontogenic cyst are treatment approach to this pathology. The aim of this study was to evaluate the effectiveness of the decompression as the primary treatment of the cystic lesions of the jaws and them reduction rates involving different factors. Material and Methods: 23 patients with odontogenic cysts of the jaws, previously diagnosed by anatomical histopathology (follicular cysts (7) and radicular cysts (16)) underwent decompression as an initial treatment. Clinical examination and pre and post panoramic radiograph were measured and analyzed. In addition, data as gender, age, time reduction and location of the lesion were collected. Results: Significant results were obtained in relation to the location of lesions and the reduction rate (p< 0.01). In a higher initial lesion, a greater reduction rate was observed (p< 0.05). Conclusions: Decompression as an initial treatment of cystic lesions of the jaws was effective; it reduces the size of the lesions avoiding a possible damage to adjacent structures. Cystic lesions in the mandible, regardless of the area where they occur will have a higher reduction rate if it is compared with the maxilla. Similar behavior was identified in large lesions compared to smaller (AU)


No disponible


Assuntos
Humanos , Cistos Odontogênicos/cirurgia , Descompressão Cirúrgica/métodos , Cistos Maxilomandibulares/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Cisto Radicular/cirurgia , Cisto Folicular/cirurgia
15.
Med. oral patol. oral cir. bucal (Internet) ; 22(5): e651-e659, sept. 2017. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-166662

RESUMO

Background: The study of osteoblasts and their osteogenic functions is essential in order to understand them and their applications in implantology. In this sense, this study try to study BMP-2 production and bone matrix deposition, in addition to other biological variables, in osteoblasts cultured on a rough double acid-etched titanium surface (Osseotite®, Biomet 3i, Palm Beach Garden, Florida, USA) in comparison to a smooth titanium surface (machined) and a control Petri dish. Material and Methods: An in vitro prospective study. NHOst human osteoblasts from the femur were cultured on three different surfaces: Control group: 25-mm methacrylate dish (n = 6); Machined group: titanium discs with machined surface (n = 6) and Experimental group: titanium discs with a double acid-etched nitric and hydrofluoric Osseotite® acid surface (n = 6). A quantification of the mitochondrial membrane potential, and studies of apoptosis, mobility and adhesion, bone productivity (BMP-2) and cellular bone synthesis were carried out after culturing the three groups for forty-eight hours. Results: A statistically significant difference was observed in the production of BMP-2 between the experimental group and the other two groups (22.33% ± 11.06 vs. 13.10% ± 5.51 in the machined group and 3.88% ± 3.43 in the control group). Differences in cellular bone synthesis were also observed between the groups (28.34% ± 14.4% in the experimental group vs. 20.03% ± 6.79 in the machined group and 19.34% ± 15.93% in the control group). Conclusions: In comparison with machined surfaces, Osseotite® surfaces favor BMP-2 production and bone synthesis as a result of the osteoblasts in contact with it (AU)


No disponible


Assuntos
Humanos , Calcificação Fisiológica , Osteoblastos , Proteína Morfogenética Óssea 2/farmacocinética , Técnicas In Vitro , Estudos Prospectivos , Proteínas do Citoesqueleto/fisiologia , Apoptose/fisiologia , Matriz Óssea/crescimento & desenvolvimento , Sobrevivência Celular/fisiologia
16.
J Dent ; 63: 85-93, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28587977

RESUMO

OBJECTIVES: To evaluate the two-year survival rate (SR) and marginal bone loss (MBL) of fixed dental prostheses (FDPs) supported by straight (S) and tilted (T) implants under the influence of diverse study variables. METHODS: A prospective investigation comprising 21 patients provided with a total of 27 maxillary screw-retained restorations fixed to 70 dental implants was developed. Two groups of implants were considered depending on their inclination with respect to the occlusal plane: Group 1 (S, n=37): straight/axial implants and Group 2 (T, n=33): tilted/angled fixations. Each FDP was supported by a combination of S and T implants. SR and MBL were assessed at the time of loading and two years after surgery. Patient-, surgical- and/or rehabilitation-related information was gathered. Data were statistically analysed at the α=0.05 significance level. RESULTS: After 24 months, a 100% SR was achieved and the MBL of S and T implants were statistically similar. T implants located in the molar region showed lower MBL than did those replacing premolars (p=0.031). CONCLUSIONS: Upright and angled fixations inserted at posterior maxillary areas resulted in comparable survival rates and peri-implant MBL after two years. The marginal bone resorption around tilted implants depended on their location. CLINICAL SIGNIFICANCE: Screw-retained restorations fixed to straight and tilted implants seem to be a safe treatment option in posterior atrophic maxillae.


Assuntos
Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária/estatística & dados numéricos , Carga Imediata em Implante Dentário , Maxila/cirurgia , Adulto , Idoso , Perda do Osso Alveolar , Dente Pré-Molar , Parafusos Ósseos , Dente Suporte , Implantação Dentária Endóssea/métodos , Implantes Dentários , Análise do Estresse Dentário , Prótese Parcial , Feminino , Humanos , Masculino , Seio Maxilar , Pessoa de Meia-Idade , Dente Molar , Estudos Prospectivos , Espanha
17.
Med. oral patol. oral cir. bucal (Internet) ; 22(2): e242-e250, mar. 2017. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-161243

RESUMO

BACKGROUND: The use of cold plasmas may improve the surface roughness of poly(lactic-co-glycolic) acid (PLGA) membranes, which may stimulate the adhesion of osteogenic mediators and cells, thus accelerating the biodegradation of the barriers. Moreover, the incorporation of metallic-oxide particles to the surface of these membranes may enhance their osteoinductive capacity. Therefore, the aim of this paper was to evaluate the reliability of a new PLGA membrane after being treated with oxygen plasma (PO2 ) plus silicon dioxide (SiO2 ) layers for guided bone regeneration (GBR) processes. MATERIAL AND METHODS: Circumferential bone defects (diameter: 11 mm; depth: 3 mm) were created on the top of eight experimentation rabbits' skulls and were randomly covered with: (1) PLGA membranes (control), or (2) PLGA/ PO2 /SiO2 barriers. The animals were euthanized two months afterwards. A micromorphologic study was then performed using ROI (region of interest) colour analysis. Percentage of new bone formation, length of mineralised bone, concentration of osteoclasts, and intensity of ostheosynthetic activity were assessed and compared with those of the original bone tissue. The Kruskal-Wallis test was applied for between-group com a significance level of a=0.05 was considered. RESULTS: The PLGA/PO2 /SiO2 membranes achieved the significantly highest new bone formation, length of mineralised bone, concentration of osteoclasts, and ostheosynthetic activity. The percentage of regenerated bone supplied by the new membranes was similar to that of the original bone tissue. Unlike what happened in the control group, PLGA/PO2 /SiO2 membranes predominantly showed bone layers in advanced stages of formation. CONCLUSIONS: The addition of SiO2 layers to PLGA membranes pre-treated with PO2 improves their bone-regeneration potential. Although further research is necessary to corroborate these conclusions in humans, this could be a promising strategy to rebuild the bone architecture prior to rehabilitate edentulous areas


Assuntos
Animais , Coelhos , Regeneração Tecidual Guiada/métodos , Silicones/uso terapêutico , Plasma , Poliglactina 910/uso terapêutico , Modelos Animais de Doenças , Osso e Ossos/anormalidades , Nanocompostos/uso terapêutico
18.
J Dent ; 55: 82-91, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27746332

RESUMO

OBJECTIVES: To validate the 'Quality of Life related to function, aesthetics, socialization, and thoughts about health-behavioural habits (QoLFAST-10)' questionnaire for assessing the whole concept of oral health-related quality of life (OHRQoL) of implant-supported fixed partial denture (FPD) wearers. METHODS: 107 patients were assigned to: Group 1 (HP; n=37): fixed-detachable hybrid prostheses (control); Group 2 (C-PD, n=35): cemented partial dentures; and Group 3 (S-PD, n=35): screwed partial dentures. Patients answered the QoLFAST-10 and the Oral Health Impact Profile (OHIP-14sp) scales. Information on global oral satisfaction, socio-demographic, prosthetic, and clinical data was gathered. The psychometric capacity of the QoLFAST-10 was investigated. The correlations between both indices were explored by the Spearman's rank test. The effect of the study variables on the OHRQoL was evaluated by descriptive and non-parametric probes (α=0.05). RESULTS: The QoLFAST-10 was reliable and valid for implant-supported FPD wearers, who attained comparable results regardless of the connection system being cement or screws. Both fixed partial groups demonstrated significantly better social, functional, and total satisfaction than did HP wearers with this index. All groups revealed similar aesthetic-related well-being and consciousness about the importance of health-behavioural habits. Several study variables modulated the QoLFAST-10 scores. CONCLUSIONS: Hybrid prostheses represent the least predictable treatment option, while cemented and screwed FPDs supplied equal OHRQoL as estimated by the QoLFAST-10 scale. CLINICAL SIGNIFICANCE: The selection of cemented or screwed FPDs should mainly rely on clinical factors, since no differences in patient satisfaction may be expected between both types of implant rehabilitations.


Assuntos
Prótese Parcial Fixa , Prótese Dentária Fixada por Implante , Estética Dentária , Hábitos , Humanos , Saúde Bucal , Satisfação do Paciente , Qualidade de Vida , Socialização
19.
J Dent ; 49: 22-32, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27134045

RESUMO

OBJECTIVES: To validate a new index for assessing the whole concept of oral health-related quality of life (OHRQoL) of implant-prosthesis wearers. METHODS: 113 patients who were not requesting dental treatment were assigned to: Group 1 (CD; n=38): complete denture users (control); Group 2 (IO; n=38): implant overdenture wearers; and Group 3 (HP; n=37): hybrid implant prosthesis users. Patients answered the newly-designed 'Quality of Life related to Function, Aesthetics, Socialization, and Thoughts about health-behavioural habits' (QoLFAST-10) and the Oral Health Impact Profile (OHIP-20sp) questionnaires. Information on global oral satisfaction, socio-demographic, clinical, and prosthetic-related data were gathered. The QoLFAST-10 was investigated for reliability and validity. The Spearman's test determined the correlations between both indices' scores. Descriptive and non-parametric probes were run to assess the influence of the study variables on the OHRQoL (α=0.05). RESULTS: The QoLFAST-10 confirmed its psychometric capacity. HP wearers reported significantly better global and functional satisfaction than did IO wearers. The latter revealed significantly less consciousness about the importance of health-behavioural habits than did CD and HP groups. The level of education, complaints about the mouth, and the global oral satisfaction measures significantly modulated the QoLFAST-10 scores. CONCLUSIONS: Implant overdentures supplied lower functional and global satisfaction than did hybrid prostheses, and represent the least predictable option concerning the maintenance of the restoration. CLINICAL SIGNIFICANCE: The QoLFAST-10 may help in estimating the impact of implant restorations on patients' well-being. In this regard, hybrid prostheses seem to be the implant treatment of choice when compared with overdentures.


Assuntos
Revestimento de Dentadura , Prótese Dentária Fixada por Implante , Humanos , Saúde Bucal , Satisfação do Paciente , Qualidade de Vida , Reprodutibilidade dos Testes
20.
J Dent ; 47: 71-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26850906

RESUMO

OBJECTIVES: Guided bone regeneration (GBR) processes are frequently necessary to achieve appropriate substrates before the restoration of edentulous areas. This study aimed to evaluate the bone regeneration reliability of a new poly-lactic-co-glycolic acid (PLGA) membrane after treatment with oxygen plasma (PO2) and titanium dioxide (TiO2) composite nanoparticles. METHODS: Circumferential bone defects (diameter: 10mm; depth: 3mm) were created on the parietal bones of eight experimentation rabbits and were randomly covered with control membranes (Group 1: PLGA) or experimental membranes (Group 2: PLGA/PO2/TiO2). The animals were euthanized two months afterwards, and a morphologic study was then performed under microscope using ROI (region of interest) colour analysis. Percentage of new bone formation, length of mineralised bone formed in the grown defects, concentration of osteoclasts, and intensity of osteosynthetic activity were assessed. Comparisons among the groups and with the original bone tissue were made using the Kruskal-Wallis test. The level of significance was set in advance at a=0.05. RESULTS: The experimental group recorded higher values for new bone formation, mineralised bone length, and osteoclast concentration; this group also registered the highest osteosynthetic activity. Bone layers in advanced formation stages and low proportions of immature tissue were observed in the study group. CONCLUSIONS: The functionalised membranes showed the best efficacy for bone regeneration. CLINICAL SIGNIFICANCE: The addition of TiO2 nanoparticles onto PLGA/PO2 membranes for GBR processes may be a promising technique to restore bone dimensions and anatomic contours as a prerequisite to well-supported and natural-appearing prosthetic rehabilitations.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Regeneração Tecidual Guiada/métodos , Ácido Láctico/farmacologia , Membranas Artificiais , Nanocompostos/química , Oxigênio/química , Gases em Plasma/química , Ácido Poliglicólico/farmacologia , Titânio/química , Animais , Doenças Ósseas/cirurgia , Calcificação Fisiológica/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/química , Regeneração Tecidual Guiada/instrumentação , Osteoclastos/efeitos dos fármacos , Osteoclastos/patologia , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Coelhos , Reprodutibilidade dos Testes , Tecidos Suporte/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...